Your basket is empty
Home > Laboratory > Viscosity > Rheometer > DVNext Cone/Plate Rheometer > LV Low Viscosity > LVDVNX CP Rheometer PJ 230V UK Brookfield Ametek XDVNXLVCJG0G00

LVDVNX CP Rheometer PJ 230V UK Brookfield Ametek XDVNXLVCJG0G00
Enlarge

LVDVNX CP Rheometer PJ 230V UK Brookfield Ametek XDVNXLVCJG0G00

PART NO: B-XDVNXLVCJG0G00

Brookfield LVDV NEXT Cone & Plate Rheometer, Jewel Pivot,230V UK

The DVNext, now with optional magnetic cone/plate.

The DVNext Wells-Brookfield Cone/Plate Rheometer gives researchers a sophisticated instrument for routinely determining absolute viscosity of fluids in small sample volumes. Its cone and plate geometry provides the precision necessary for development of complete rheological data.


FEATURES AND BENEFITS
Determine absolute viscosity of small samples (0.5–2.0 mL)
Precise shear rates for determining a materials flow curve behavior
Rapid temperature control due to small sample size
Optional magnetic coupling attachment for simplified spindle attachment and removal
Electronic gap adjustment for simplified setup and increased throughput
Touch Screen Display available on DVNext Rheometers
Auto-zero function to ensure precision torque measurement
Auto-range function to define full-scale-range (FSR) for all spindle/speed combinations
Torque measurement accuracy: 1% of full-scale range
Repeatability: 0.2% of full-scale range


PRINCIPLE OF OPERATION

The DVNext Wells-Brookfield Cone/Plate Rheometer is a precise torque meter which is driven at discrete rotational speeds. The torque measuring system, which consists of a calibrated beryllium-copper spring connecting the drive mechanism to a rotating cone, senses the resistance to rotation caused by the presence of sample fluid between the cone and a stationary flat plate.

The resistance to the rotation of the cone produces a torque that is proportional to the shear stress in the fluid. This reading is easily converted to absolute centipoise units (mPa·s) from pre-calculated range charts. Alternatively, viscosity can be calculated from the known geometric constants of the cone, the rate of rotation, and the stress related torque.

The correct relative position of cone and plate is obtained by following a simple mechanical procedure without the need for external gauges or supplementary instrumentation.

The stationary plate forms the bottom of a sample cup which can be removed, filled with 0.5 ml to 2.0 ml of sample fluid (depending on cone in use), and remounted without disturbing the calibration. The sample cup is jacketed and has tube fittings for connection to a constant temperature circulating bath.

The system is accurate to within ±1.0% of full-scale range. Reproducibility is to within ±0.2%. Working temperature range is from 0°C to 100°C.

Various cone spindles are available for use with the DVNext Wells-Brookfield Cone/Plate Rheometer. Cone spindles may be purchased and will be calibrated for use with the same sample cup.


VERSATILITY OF APPLICATION

The DVNext Wells-Brookfield Cone/Plate Rheometer provides a wide variety of shear rates and viscosity ranges, which can be further extended by using interchangeable cone spindles. Different models can be selected to meet the specific range of viscosities and shear rates required.

Shear rates as high as 1875 sec-1 (DVNextCP) can be achieved.

The small sample volume required permits rheological evaluations to be made on materials where sample availability is limited, such as biological fluids and thick film coatings that contain precious metals.

All wetted parts are stainless steel for corrosion resistance and ease of cleaning. Optional purge fitting, luer fitting, and embedded temperature probe available.


UPDATED GAP SETTINGS

The DVNext Wells-Brookfield Cone/Plate Rheometer is supplied with an advanced Electronic Gap Setting feature. This technology allows faster set-up time and minimizes the possibility of gap adjustment errors. A simple turn of the micrometer adjustment ring and the gap is set, reducing the time associated with manual detection methods.

The new electronic gap setting system is now a standard feature on the DVNext Wells-Brookfield Cone/Plate Rheometer. This instrument provides precise shear profiles necessary to determine viscosity and develop rheological data.


Key Features of DVNext Rheometer

  • Magnetic Coupling Attachment: Simplifying the process by replacing the traditional EZ-lock system.
  • Barcode Scanner Integration: Enhancing user convenience with quick and efficient sample identification.
  • Digital Leveling: Ensuring accurate and consistent measurements.
  • Gel-Timer Functionality: Providing precise control over gel time measurements.
  • Start-up Wizard: Offering an intuitive setup process for seamless operation.
  • Optional 17025 Calibration: Ensuring the highest standard of accuracy and compliance.

Standard Version

  • Digital Leveling: Maintain precise instrument balance for accurate results.
  • Start-up Wizard: Facilitates easy and quick setup.
  • Gel-Timer Functionality: Perfect for applications requiring precise timing.
  • Optional Magnetic Coupling Attachment: Simplifies spindle attachment and removal, enhancing user-friendliness.
  • Optional Barcode Scanner: Speeds up sample handling and data entry.
  • 17025 Calibration (Optional): Ensures your measurements meet international standards.
ManufacturerBrookfield Ametek
Manufacturer P/nXDVNXLVCJG0G00