Xylem - WTW N5/25 Nitrite No2 252074
PART NO: X-252074
Price: £115.56
Out of Stock (Ships in approx. 2 weeks)
Photometric test kit for measurement of Nitrite NO2
Available ranges:
0.010 - 0.700 mg/l NO2-N
0.03 - 2.30 mg/l NO2
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.02 - 0.55 mg/l NO2-N; 0.07 - 1.81 mg/l NO2
Additional information:
For use with seawater.
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation
Available ranges:
0.010 - 0.700 mg/l NO2-N
0.03 - 2.30 mg/l NO2
Number of tests: 25 (Reaction cuvettes test)
Sample volume required: 5ml
Cuvette type: round
Compatible with photometers:
photoLab S6
photoLab S12
photoLab Spectral
pHotoFlex 0.02 - 0.55 mg/l NO2-N; 0.07 - 1.81 mg/l NO2
Additional information:
For use with seawater.
Reaction:
Griess Reaction analog EN 26777 LD 10 and US Standard Method 4500-NO2- B. NO2-1,2: Diazotisation
00609: Iron reaction in acid solution with Fe(II)-ethylendiammonium sulfate
Applications:
Waste water, ground and surface water, drinking water, sea water, food and soils after corresponding sample preparation
Photometer photoLab® and photoFlex®, stored test protocols A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® Spektral B: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® Spektral C: Stored in photoFlex® and photoFlex® Turb® Reagent-free tests: Cu - copper plating bath, 690nm, 820nm - copper plating bath - B CrO3 - chromium plating bath - chromium plating bath - B Ni - nickel plating bath - nickel plating bath - B HZ - Hazen colour - Hazen colour - B IFZ - iodine number, 340nm, 455nm - iodine number - B m-1 (DFZ) - colouring - FB445 - B, C m-1 (DFZ) - colouring - FB525 - A, C m-1 (DFZ) - colouring - FB620 - B, C FAU - turbidity 620 - T620 - B E - extinction - extinction - A, B, C SAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm) Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®. Product Specification: Product Type: N5/25 Description: NO2-N, Nitrite For: A, C Unit: 0.010 - 0.700 mg/l No. of determinations: 25 | |
Catalogue Number | 9.920 960 |
Manufacturer | Xylem - WTW |
Manufacturer P/n | 252074 |
Description | Nitrite, NO2-N |
Type | N5/25 |
Unit | 0.010 - 0.700 mg/l |
For | A, C |
No. of determinations | 25 |
PK | 1 |
Search words | Photometers test protocols |